Bildmarke ThyssenKrupp
Sitemap Search German French
Submenue
Home Company Products Publications Press Career Contact
PowerCore® C
  PowerCore® H
  Guaranteed values
  Correlation table
  Dimension conversion
  Dimensions
  Geometric tolerances
  Other characteristics
  Insulation types
  Packing
  Typical physical properties
  Further processing hints
Search on tkes.com

Other characteristics and tolerances



Residual curvature 
Edge camber 
Max. distance for a sample 500 mm in length applicable for width > 150 mm
35 mm
Max. edge camber for a measuring length of 1,500 mm applicable for width > 150 mm
0.5 mm

Deviation from the shearing line due to internal stresses 
Flatness (wave factor) 
Max. measured gap within a strip length of 1,500 mm applicable for width
> 500 mm
1.0 mm
Max. wave factor applicable for width > 150mm
1.5%

The measuring methods for thickness and width are given in the product standards EN 10107 and IEC 60404-8-7.

All other measuring methods and definitions are given in EN10251 and IEC 60404-9.


The quoted values are in many cases better than those
specified in the EN or IEC-Norm.
Burr height (only for slit width) 
Max. burr height
0.025 mm